Back to serviceIllustrative example · not for operational use
BIRWICKS

ILLUSTRATIVE CLIENT REPORT

LEV thorough examination & testing

Example Fabrication · Welding bay

Report reference
BIR-LEV-26001
Inspection date
12 September 2026
Prepared by
BIRWICKS Engineering Inspection & Assurance
Issue
Example issue 01

01 · Executive summary

Inspection position at a glance

This example demonstrates how the completed LEV report is presented to a customer. It combines a concise overview with the detailed evidence needed to understand and manage each recorded item.

3Assets reviewed
1Satisfactory / closed
1Advisory
1Priority actions

02 · Scope

What was reviewed

Illustrative thorough-examination report covering hood condition, airflow, ductwork, filtration and observed capture performance.

Example limitation

This demonstration assumes a visual and functional review of accessible equipment. Internal components, destructive testing and areas not made available are excluded unless specifically agreed.

03 · Asset register

Equipment included in the report

ReferenceEquipmentLocationPosition
LEV-001Welding extraction armBay 2Action required
LEV-002Grinding booth extractionBay 5Advisory
LEV-003Filter unitExternal plantSatisfactory

04 · Detailed findings

Evidence, significance and next action

LEV-001Significant

Capture performance below reference

Evidence: Observed capture at the working position was inconsistent and requires competent review.

Recommended action: Arrange review by an appropriate competent person, record the completed action and verify close-out.

Engineer measuring airflow at a welding extraction hood — LEV-001Illustrative evidence photograph · LEV-001
LEV-002Advisory

Flexible duct showing wear

Evidence: Surface deterioration is visible near the articulated joint.

Recommended action: Arrange review by an appropriate competent person, record the completed action and verify close-out.

Engineer measuring airflow at a welding extraction hood — LEV-002Illustrative evidence photograph · LEV-002
LEV-003Satisfactory

Filter housing condition

Evidence: Housing and accessible seals appeared serviceable at the time of examination.

Recommended action: Maintain the current controls and retain this record with the equipment history.

Engineer measuring airflow at a welding extraction hood — LEV-003Illustrative evidence photograph · LEV-003

05 · Photographic evidence

Images remain linked to the correct equipment and finding

Full-size photographs are retained with their captions, asset reference and related finding so the customer can understand what was observed without relying on a separate folder of images.

Engineer measuring airflow at a welding extraction hood — view 1
LEV-001Capture performance below reference
Engineer measuring airflow at a welding extraction hood — view 2
LEV-002Flexible duct showing wear
Engineer measuring airflow at a welding extraction hood — view 3
LEV-003Filter housing condition

06 · Corrective-action register

A clear route to close-out

LEV-001 · Capture performance below referenceOwner: Site engineering · Target: Immediate review · Status: Open
LEV-002 · Flexible duct showing wearOwner: Site engineering · Target: Planned action · Status: Open
LEV-003 · Filter housing conditionOwner: Site engineering · Target: Planned action · Status: Open
Report conclusion

This illustrative issue shows the structure customers receive. Final conclusions always reflect the agreed scope, evidence collected and limitations recorded during the actual inspection.